Then plug theWifiData Logger into the port and be sure to secure it by tightening the black connector. Have contacted the company who sold me it. It's probably just the datalogger that's lost connection. To connect to the WIFI stick go to the WIFI connections and select the AP_XXXXXXX and connect. This is the same data as can be sent to the ginlogmonitoring.com website for centralised data collection. Enter the password for the network and then tap "Next". To view the purposes they believe they have legitimate interest for, or to object to this data processing use the vendor list link below. Just note that the Freshdesk service is pretty big on some cookies (we love the choco-chip ones), and some portions of Freshdesk may not work properly if you disable cookies. Open a web browser and enter "10.10.100.254" into the address bar 4. You should see a message that says "Bound Successfully" and now you will need to set up the logger on the localWiFinetwork. it tries to reconnect itself vut you can just unplug it and plug it back. Users can easily check device lnformatlon by logging In the monitoring center. Open the SolisCloud app on your phone. Sorry we couldn't be helpful. If its not broadcasting conduct this procedure - https://www.youtube.com/watch?v=nUjcDcY8-Ws - If that doesn't fix the issue of it broadcasting please contact your local Solis Service Center and RMA the WIFI Stick. Trying to connect to 5GHZ signal (Solis DLS-W only supports 2.4 ghz signals) 2. SolisCloud intelligent software enables systems to be commissioned, monitored and maintained remotely saving time and money for installers and empowering system owners with all the data they need. We and our partners use cookies to Store and/or access information on a device. Solis S1-W4G-ST WiFi & Cellular Data Logger Set Up Guide; Solis S3-WIFI-ST Wi-Fi Data Logger Setup Guide; Solis DLS-W WiFi Data Logger Installation Guide; Solis Cellular Data Logger Installation Guide; Solis DLS-C Cellular Data Logger - Carrier Compatibility; Replacing a Solis Data Logger; WiFi password changed The content of the text message is . I have done a bit of Googling and the only negative thing I have read about the data logger is that it can lose it's wifi connection easily. See if this helps you out https://www.youtube.com/watch?v=0F0aGeTOYw8. SolisCloud is the new generation of intelligent PV system monitoring. This process can also be used to move a Solis Data Logger from one site to another. Step 2: If it is a new data logger, please configure it first, then click the Willi configure. If failed, re-do the configuration process or contact the after-sale engineers. Solis is one of the oldest and largest global string inverter specialists that manufactures single-phase inverters, three phase inverters and energy stroage inverters for residential, commercial and utility scale PV systerms . We use cookies to try and give you a better experience in Freshdesk. Status indicator, easy to display working status, RESET button, one key to send data, convenient debugging, Number of connected inverters (Connect the inverters by RS485 cables. Step 6: Plant creation succeeds. 2. If its not pingable, the password is good, the signal strength is good then login to the router and check the customers firewall protections. Then click the Its flashing. Things (IOT). You can rerun the wizard and see if that works. Shows the connection status between the datalogger and the server. Step 5: Long press the Reset button for 5 seconds until the yellow and green LEDs are quickly flashing. AC Voltage Offset Procedure and Firmware Requirements, Service - Modbus Issues - Troubleshooting, LCD Protective Sticker Replacement Procedure. If you hate cookies, or are just on a diet, you can disable them altogether too. Select Network, fill in the IP address assigned by the router/network administrator, Let us know how can we improve this article! Step 4: Click , make sure the phone is connected to router WiFi, and switch back to the page to fill in the WiFi password, then move to the next step. cordless phone, concrete wall, PV panel and metal wall, to ensure the communication quality. Yes my data logger also glows red as well, does appear to be a LED keepalive in the unit to show its still transmitting data to the mothership. Copyright@2020 Ginlong Technologies All rights reserved. Then click Done. Did you find it helpful? Hi all, The AutoSave Draft feature is now disabled across the site. I have tried different settings with the data logger setup without having any luck. Plug the logger into the inverter - be sure the inverter is on with at least DC power, Open the Wi-Fi settings on your phone and then search for new networks, Look for a network called "Solis_XXXXXXXXXX" the "XXXXXXXX" should be the serial number of the logger, Open a browser on your phone and enter 10.10.100.254 into the address bar, Enter "admin" for the password and "123456789" for the password then hit Log In, Go to Quick Set and then tap Search in the top left corner, Select the local Wi-Fi network that you wish to use, Enter the Wi-Fi network password (be sure that it is correct) and then tap Save, If everything was done correctly, the "Solis_XXXXX" network should disappear and the NET/COM lights on the logger should begin flashing, At this point you can go to SolisCloud and add the data logger to your plant, Use the scanner to scan the QR code sticker on the logger, Place your hand behind the logger if the scanner is not working (this helps it to focus), If you are still not having luck scanning the logger you can enter the serial number manually, Go to the Device tab on your plant and then to the Data Logger tab, The data logger should now be displayed here with note about when it last reported. Did you get a response from Ginlong? how to set up wifi stick in Solis inverter | Solis Data Logger Setup - YouTube 0:00 / 4:51 how to set up wifi stick in Solis inverter | Solis Data Logger Setup Infinite Laboratory. This equipment should be installed and operated with a minimum distance of 20cm between the radiator & your body. 1. You can learn more about what kind of cookies we use, why, and how from our Privacy policy. I used to have problems like that all the time until I got a wifi mesh system in the house. Copyright@2019 Ginlong Technologies All rights reserved, Dec-17-2019, Go Solis Webinar: 2020 CA Solar Mandate Compliance with Solis Inverters, Feb-11-2020, Go Solis Webinar: New Solis 125K 1500V Inverters plus AlsoEnergy: Better ROI for 2-40 MW Systems, Mounting, Wiring, and Commissioning 4G Single Phase Inverter - Video, Solis and the Tigo TS4 Platform; Tested and Harmonized Commercial Inverter 690.12 Rapid Shutdown Solutions, Contacting Technical Support for Solis Partners, Contacting Technical Support for Your Region, Go Solis 2020 Webinar #7: Testing Solis Inverters Beyond Certifications with PV Evolution Labs, Go Solis Mini Exchange#1: An Introduction to Energy Storage System, Go Solis Webinar #1: 2020 California Solar Mandate with Solis Inverters (12/17/2019, U.S.), Go Solis Webinar #2: The New Solis 125K 1500V Inverters plus Also Energy (2/11/2020, U.S.), Go Solis Webinar #3: Solis Hybrid Energy Storage Inverter with LG Chem (2/11/2020, U.S.), Go Solis Webinar #4: Solis Commercial Inverters (4/21/2020, U.S.), Go Solis Webinar #5: Solis inverters and SunSpec Alliance (5/5/2020, U.S.), Go Solis Webinar #6: Solis and Tigo TS4 Platform - Tested and Harmonized Commercial Inverter 690.12 Rapid Shutdown Solutions, Go Solis Webinar #8 Solis Inverters and SunSpec Alliance: The Importance of SunSpec CSIP 2030.5, Ginlong Solis: Standard Lead Time from Ningbo to USA/Canada, How to Determine the Firmware Version of your Solis Inverter, Lowering Output Power of Single Phase Solis Inverter, MA Compatibility Between Single Phase 4G and 2G inverters, Solis 3PH and CSI GS Product Number and Description 20180331, Starting Serial Numbers and HMI VER- ISO-NE / Rule 21 P1 and P3, String Sizing for 1P and 3P Inverters. Firmware Version: 3.16.9. i have recently installed a solar inverter which has a data logger > having an issue connecting it to my wifi network but it works fine with . Establecer el estndar de red personalizado Definido por usuario, Valores de la configuracin USER DEF para red 240v y 480v, Procedimiento de actualizacin remota de firmware, Reduccin de la potencia de salida del inversor Solis monofsico, Instalacin de cable RS-485 con conector circular, Configuracin de la direccin en inversor trifsico, Restablecer WiFi-Stick a la configuracin de fbrica, Registro de usuario final al sistema de monitoreo. Verify the WIFI stick is broadcasting by looking for the WIFI transmitter AP_XXXXXXXXXX in your WIFI SSID connections. In order to to set an IP address you can use a Mobile Phone, Tablet or Computer. Go to your web browser - Input 10.10.100.254 4. If the WIFI stick shows the inverter but you don't have data on the monitoring portal follow these steps: If it is not pingable verify the router password again. Internal DC Short: In the inverter head, or the wirebox? Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Note that all scripts use Python 3. In general you want to ensure the router is not blocking the IP address from the WIFI stick. Step2: Connect the datalogger to the corresponding 4-pin COM port of the inverter. Comment * document.getElementById("comment").setAttribute("id","afdcdc86cefb6e10bf27816a9d02011c");document.getElementById("afe6277d1c").setAttribute("id","comment"); Save my name, email, and website in this browser for the next time I comment. We use cookies to try and give you a better experience in Freshdesk. Your email address will not be published. We use cookies to try and give you a better experience in Freshdesk. Solis WIFI and LAN Data Logger Datasheet.pdf, Solis WIFI Logger Installation Manual v2.4 (1).pdf. You will benefit from upgraded accurate fault alarm messaging that is adjustable to notify you within hours that fit meet your needs. We and our partners use data for Personalised ads and content, ad and content measurement, audience insights and product development. Solis WiFi Loggers Network Strength Requirements, Solis Home Professional - Generation 2 Monitoring Platform, Account Transfer to New Monitoring Platform, Adding End-User (Customer) to Plant for Monitoring Access, Selecting Inverter Drivers on AlsoEnergy PowerTrack Monitoring, Inaccurate Production Data on Monitoring Portal, Registering Installer Account on G2 Portal, Setting Up Agency Access to Plant Monitoring, Enabling SMS Notifications on SolisCloud App, How to Create an Installer Account on SolisCloud, Create Sub-Organizations, & Manage Sub-Accounts, Deteccin falla de arco y solucin de problemas, Pantalla en blanco / LCD en blanco / Sin luces. Go to the web browser and go to 10.10.100.254 and password is admin:admin. Router signal strength is low 4. Shows the connection status between the datalogger and the inverter. Michael is the author of this solution article. If you run through the setup wizard and are still having problems I suggest you contact them. All is fine for about a week and then I noticed that the system would go offline a couple of times throughout the day (morning and night) with varying durations. Step 6: Wait for around 10 seconds. Solis S1-W4G-ST WiFi & Cellular Data Logger Set Up Guide; Solis S3-WIFI-ST Wi-Fi Data Logger Setup Guide; Solis DLS-W WiFi Data Logger Installation Guide; Solis Cellular Data Logger Installation Guide; Solis DLS-C Cellular Data Logger - Carrier Compatibility; Replacing a Solis Data Logger; WiFi password changed Required fields are marked *. Establecer el estndar de red personalizado Definido por usuario, Valores de la configuracin USER DEF para red 240v y 480v, Procedimiento de actualizacin remota de firmware, Reduccin de la potencia de salida del inversor Solis monofsico, Instalacin de cable RS-485 con conector circular, Configuracin de la direccin en inversor trifsico, Restablecer WiFi-Stick a la configuracin de fbrica, Registro de usuario final al sistema de monitoreo. solis S4-GPRS GPRS Stick Datalogger Installation Guide, solis SOL-DLS-W Data Logger Wifi Stick User Guide, DAIKIN BRP069B45 WiFi Adapter Installation Guide, ideal lux 306445 Clara PL Square 4000K Ceiling Light Owners Manual, Microderm GLO NVD-MGM-GR1802 Blackhead Remover Pore Vacuum User Guide, AVALON A3F Bottom Loading Water Cooler Water Dispenser User Manual, boAt Wave Lynk Voice Premium Smartwatch User Manual, motorline RAP50 Microwave Presence Sensor User Manual, kbice FDFM1JA01 Self Dispensing Nugget Ice Machine User Guide, LUMINAR EVERYDAY 59250 2ft LED Linkable Plant Grow Light Owners Manual, Viatom Blood Pressure Monitor BP2 & BP2A User Manual. Data Logger into the port and be sure to secure it by tightening the black connector. Once the logger is scanned it will be added to the system. Connect one end of an ethernet cable to LAN stickand other end directly to a computer. Enter the password for the network and then tap "Next". Internal DC Short: In the inverter head, or the wirebox? I too have recently tried to connect to the Ginlong data logger without success. When the network environment of the plant has a firewall, you need to add the server information to the white list of the firewall. Insert the datalogger to the inverter COM port. What do I do next? If you would like to change your settings or withdraw consent at any time, the link to do so is in our privacy policy accessible from our home page.. Let us know how can we improve this article! Technician check pins 3 and 4 for 1.5 - 1.7 VDC, 2. Questions and discussion about solar, batteries, and other renewable energy technology.
Dougherty Dozen Income, Articles S